Penetration Grade Bitumen Specification

Type of BitumenGrade of Bitumen
Penetration Grade10-20, 20-30, 30-40, 40-50, 50-70,60-70, 80-100, 85-100, 100-120

Penetration Grade Analysis

AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/1060-70ASTM D5
Softening Point °C46 MinASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
Viscosity@60 °CP2000 ± 400ASTM D2171
Viscosity@135 °CcSt300 MinASTM D2170
AnalysisUnitLimitTest Method
Density @25 °CKg/m31000-1050ASTM D7 or D3289
Penetration at 25°CMm/1085-100ASTM D5
Softening Point °C42 MinASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.5 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
Viscosity@60 °CP1000 ± 200ASTM D2171
Viscosity@135 °CcSt250 MinASTM D2170
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/10100-120ASTM D5
Softening Point °C44-56ASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C240-300ASTM D92
Solubility in Trichloroethylene Wt%99.5 MinASTM D2042
Spot test --NegativeAASHTO T102
AnalysisUnitLimitTest Method
Density @25 °CKg/m31000-1050ASTM D7 or D3289
Penetration at 25°CMm/1080-100ASTM D5
Softening Point °C42 MinASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.5 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
Viscosity@60 °CP1000 ± 200ASTM D2171
Viscosity@135 °CcSt250 MinASTM D2170
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/1040-50ASTM D5
Softening Point °C52-60 MinASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
Viscosity@60 °CP4000 ± 800ASTM D2171
Viscosity@135 °CcSt400 MinASTM D2170
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/1030-40ASTM D5
Softening Point °C55-63ASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/1010-20ASTM D5
Softening Point °C120ASTMD36
Ductility, 25°C(cm/s)3 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C225 MinASTM D92
Solubility in Trichloroethylene Wt%99.5 MinASTM D2042
Spot test --NegativeAASHTO T102
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/1020-30ASTM D5
Softening Point °C80-90ASTMD36
Ductility, 25°C(cm/s)3 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%20 MaxASTM D5
Flash Point°C225 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102
AnalysisUnitLimitTest Method
Density @25 °CKg/m31010-1060ASTM D7 or D3289
Penetration at 25°CMm/10100-120ASTM D5
Softening Point °C42-49ASTMD36
Ductility, 25°C(cm/s)100 MinASTM D113
Loss on HeatingWt%0.2 MaxASTIM D6
Drop in penetration after heating%30 MaxASTM D5
Flash Point°C232 MinASTM D92
Solubility in Trichloroethylene Wt%99.0 MinASTM D2042
Spot test --NegativeAASHTO T102